Coag2D 2-Channel Optical Coagulometer

2-Channel Optical Coagulometer

Download Catalogue

GST

Invoice

Best Price

Guaranteed

Description

COAG-2D (Two-channel semi-auto coagulometer) comes with a compact design and a complete test palette for clotting, chromogenic and turbidimetric tests. The device is small with a compact footprint, easy to operate, and also offers maintenance-free operation & LIS connection.

2-Channel Optical Coagulometer The Coag2D is a high-quality optical coagulometer that provides accurate and reliable measurements of blood coagulation parameters. It features two independent channels, allowing for simultaneous testing of multiple samples or running control samples alongside patient samples.
Advanced Optical Detection Technology The coagulometer utilizes advanced optical detection technology to measure clotting times and other coagulation parameters. This technology ensures precise and consistent results, enabling healthcare professionals to monitor coagulation status effectively and make informed decisions regarding patient care.
Wide Range of Coagulation Parameters The Coag2D coagulometer is capable of measuring a wide range of coagulation parameters, including prothrombin time (PT), activated partial thromboplastin time (APTT), fibrinogen, thrombin time (TT), and other clotting factors. This versatility allows for comprehensive coagulation testing and monitoring in various clinical scenarios.
User-Friendly Interface The coagulometer features a user-friendly interface with a clear and intuitive display. The interface enables easy navigation and access to various functions, making it convenient for healthcare professionals to operate the device, perform tests, and interpret the results efficiently.
Automated Calibration and Quality Control The Coag2D coagulometer offers automated calibration and quality control functions, ensuring the accuracy and reliability of test results. The system performs regular calibration procedures and allows for quality control measurements to be easily incorporated into the testing workflow, minimizing errors and maintaining high testing standards.
Compact and Space-Efficient Design The coagulometer is designed to be compact and space-efficient, making it suitable for use in various laboratory or clinical settings. Its small footprint allows for easy placement on laboratory benches or countertops without occupying excessive space, optimizing workflow efficiency and laboratory productivity.
Efficient Sample Handling The coagulometer is equipped with features that facilitate efficient sample handling. It accommodates various sample volumes, allowing for flexibility in sample collection and testing. The system also supports barcode scanning for streamlined sample identification and traceability, reducing the risk of errors and enhancing workflow efficiency.
Data Storage and Connectivity The Coag2D coagulometer includes data storage capabilities, enabling the storage of test results and patient information. It may also offer connectivity options such as USB or network connectivity, allowing for convenient data transfer, integration with laboratory information systems (LIS), or remote access to test results for analysis and reporting.
User-Defined Test Protocols The coagulometer allows users to define and customize test protocols based on specific requirements or laboratory protocols. This flexibility enables tailored testing approaches and the ability to adapt to evolving testing needs, ensuring compatibility with different reagents and optimizing laboratory workflows.
Quality and Compliance Standards The Coag2D coagulometer meets relevant quality and compliance standards, such as ISO 13485 and CE certification. This ensures that the device is manufactured and validated according to recognized quality management systems, providing confidence in its performance, reliability, and adherence to regulatory requirements.

Additional information

Weight 0.4 kg
Dimensions 5 × 10.2 × 16.5 cm
Measurement Channels

2 channels

Measurement Principle

Optical detection method

Measurement Parameters

Prothrombin Time (PT), Activated Partial Thromboplastin Time (APTT), Fibrinogen (FIB), Thrombin Time (TT), D-Dimer, Clotting Factors, and other coagulation parameters

Sample Volume

Minimum sample volume required for testing

Test Speed

Rapid testing with quick results

Calibration

Calibrated according to international standards

User Interface

Intuitive user interface with a graphical display and easy-to-use controls

Data Management

Ability to store and retrieve test results, patient information, and calibration data

Connectivity

Optional connectivity features for data transfer and integration with laboratory information systems or electronic medical records

Quality Control

Built-in quality control features to ensure accurate and reliable results

Maintenance

Low maintenance requirements with regular cleaning and calibration checks

Power Requirement

Power supply options and voltage compatibility

Operating Environment

Recommended temperature, humidity, and atmospheric conditions for optimal operation

Regulatory Compliance

Compliance with relevant regulatory standards and certifications

Additional Features

Any additional features or functionalities, such as built-in printer, touchscreen interface, barcode scanning, or custom test protocols

User Manual

Comprehensive user manual with instructions for operation, troubleshooting, and maintenance

Support and Service

Availability of technical support, training, and after-sales service

FAQs

What is a coagulometer?

A coagulometer is a medical device used to measure the blood's ability to clot. It is commonly used in laboratory and clinical settings to assess coagulation factors, monitor anticoagulant therapy, diagnose bleeding disorders, and evaluate overall hemostasis.
The Coag2D coagulometer utilizes an optical detection method to measure the clotting parameters in the blood sample. It uses light absorption or turbidity changes to determine the clotting time, allowing for accurate and reliable assessment of coagulation factors and other related parameters.
The Coag2D coagulometer can measure various parameters, including Prothrombin Time (PT), Activated Partial Thromboplastin Time (APTT), Fibrinogen (FIB), Thrombin Time (TT), D-Dimer, Clotting Factors, and other coagulation parameters. These measurements help evaluate the blood's clotting ability and diagnose clotting disorders.
The Coag2D coagulometer offers rapid testing, providing quick results for the measured parameters. The exact test duration may vary depending on the specific tests performed and the sample volume used. However, it is designed to deliver efficient and timely results for effective clinical decision-making.
Yes, the Coag2D coagulometer is equipped with data management capabilities that allow for the storage and retrieval of test results. This feature enables easy access to previous patient data, comparison of results over time, and efficient record-keeping for documentation and analysis purposes.
Yes, the Coag2D coagulometer may offer optional connectivity features. These can include data transfer capabilities and integration with laboratory information systems or electronic medical records. Connectivity allows for streamlined data management, improved workflow, and enhanced connectivity within the healthcare system.
The Coag2D coagulometer should undergo regular calibration according to the manufacturer's guidelines. Calibration ensures accurate and consistent test results. The frequency of calibration may vary, and it is important to follow the recommended calibration schedule to maintain the device's performance and reliability.
The Coag2D coagulometer typically requires regular maintenance, including cleaning and calibration checks. Proper cleaning procedures, as outlined in the user manual, should be followed to ensure the device's longevity and optimal performance. Additionally, periodic calibration checks help maintain accuracy and reliability.
Yes, the Coag2D coagulometer is designed to accommodate different sample volumes, although it has a minimum sample volume requirement. It is important to adhere to the recommended sample volume guidelines provided by the manufacturer to ensure accurate and consistent test results.

Reviews

There are no reviews yet.


Be the first to review “Coag2D 2-Channel Optical Coagulometer”