Bionet FC1400 Fetal Monitor (CTG Machine)

The FC 1400 is an antepartum touch-screen fetal monitor that detects and displays twin fetus heart rates and uterine activity in real-time on the 7” color touch-screen LCD monitor. The touch interface, along with 10 smart keys for 16 functions, makes the operation easier and faster.

Download Catalogue

SKU: MD-PM-00007 Categories: , ,

Original price was: ₹135,000.Current price is: ₹111,499.

Enquiry Now

GST

Invoice

Best Price

Guaranteed

Description

The Bionet FC1400 Fetal Monitor (CTG Machine) is an antepartum touch-screen fetal monitor that detects and displays twin fetus heart rates and uterine activity in real-time on the 7” color touch screen LCD monitor. The touch interface, along with 10 smart keys for 16 functions, makes the operation easier and faster. The built-in printer provides an easy-to-read B4 size printout for charting. Onboard memory allows you to review and print up to 72 hours of internally stored data. The USB flash drive interface provides a simple way to move the test result to PC for EMR attachment. Automatic fetal movement detection and TOCO zeroing reduce the need for staff involvement. The CTG (cardiotocography) interpretation provides the silent recommendation for NST (Non-Stress Test).

Key Features

  • Fetal Health Assessment: Provides essential data for monitoring the baby’s health during pregnancy and labor.
  • Accurate Readings: Utilizes Doppler technology to ensure precise fetal heart rate and contraction measurements.
  • Data Storage: Allows healthcare providers to maintain comprehensive records for each patient.
  • Real-Time Monitoring: Immediate feedback for timely medical interventions when needed.
  • User-Friendly: Intuitive interface for healthcare professionals of all levels.
  • Twin Pregnancy Monitoring: Suitable for tracking the progress of multiple fetuses in twin pregnancies.
  • On-the-Spot Reports: Built-in printer for quick and efficient report generation.
  • Portability: Compact design enables flexibility in various clinical settings.

Dimension 296 (W) x 305.5 (H) x 97.5 (D) mm, approx. 2.6 kg
Display 7″ TFT wide LCD screen (800 X 480)
Recorder Method: Thermal array print
Type: Roll type
Print speed:
– Real time mode: 1, 2, 3 cm/min
– Trace mode: 20, 30 cm/min
Paper feeding function
Power Input: 100 – 240 VAC, 1.5 – 0.7 A, 50 – 60 Hz / Output: 18 VDC, 2.8A
Battery (Option) Li-ion: 4 hours (charging) / 2 hours (discharging)
External Link USB flash drive
Fetal Heart Rate Input Signal: Ultrasound pulsed doppler
Ultrasound frequency: 1.0 MHz, 975 KHz
Ultrasound power: FHR detection method: Autocorrelation
FHR range: 50~210 BPM
FHR accuracy: 120~160: ±1 BPM / Except 120~160 BPM: ±2 BPM
Uterine Contraction Input Source: External Transducer with load cell
Reference Control: One touch switch, auto zeroing
Measurement range: 0~99
Fetal Movement Measurement Detection source: Ultrasound pulsed doppler, event marker
Data Storage Storage for 72 hours
Auto CTG Analysis Average Baseline FHR
Number of UC
Number of Acceleration
Number of Deceleration: Late, Early, Variable
High/Low Episode
Short term Variability
Signal Loss
* CTG Analysis results is printed out every 10 minutes (Intermediate report)
Standard Accessories Ultrasound doppler probe – 2 ea
UC probe – 1 ea
Event marker – 1 ea
Printer paper – 2 rolls
Power adaptor & cord – 1 ea
Ultrasound gel – 1 ea
Probe belt – 3 ea
Operation manual – 1 ea
Stand – 1 ea
Optional Accessories Rechargeable battery (1 ea), Cart

Additional information

Weight 3.0 kg
Dimensions 29.6 × 30.55 × 97.5 cm
Brand

Bionet

Display

7″ TFT wide LCD screen (800 X 480)

Recorder

Method: Thermal array print Type: Roll type Print speed: – Real time mode: 1, 2, 3 cm/min – Trace mode: 20, 30 cm/min Paper feeding function

Power

Input: 100 – 240 VAC, 1.5 – 0.7 A, 50 – 60 Hz / Output: 18 VDC, 2.8A

Battery (Option)

Li-ion: 4 hours (charging) / 2 hours (discharging)

Fetal Heart Rate

Input Signal: Ultrasound pulsed doppler Ultrasound frequency: 1.0 MHz, 975 KHz Ultrasound power: FHR detection method: Autocorrelation FHR range: 50~210 BPM FHR accuracy: 120~160: ±1 BPM / Except 120~160 BPM: ±2 BPM

Uterine Contraction

Input Source: External Transducer with load cell Reference Control: One touch switch, auto zeroing Measurement range: 0~99

Fetal Movement Measurement

Detection source: Ultrasound pulsed doppler, event marker

Data Storage

Storage for 72 hours

Auto CTG Analysis

Average Baseline FHR Number of UC Number of Acceleration Number of Deceleration: Late, Early, Variable High/Low Episode Short term Variability Signal Loss * CTG Analysis results is printed out every 10 minutes (Intermediate report)

Standard Accessories

Ultrasound doppler probe – 2 UC probe – 1 Event marker – 1 Printer paper – 2 rolls Power adaptor & cord – 1 Ultrasound gel – 1 Probe belt – 3 Operation manual – 1

FAQs

What is the primary purpose of the Bionet FC1400 Fetal Monitor?

It is used to monitor fetal heart rate and uterine contractions during pregnancy and labor.
It utilizes Doppler ultrasound technology for continuous heart rate monitoring.
It offers data on fetal well-being, contractions, and labor progression.
Yes, it can track the progress of multiple fetuses.
Yes, it allows for the storage and retrieval of fetal data.
Yes, it features an intuitive user interface.
It provides immediate feedback for timely interventions if necessary.
Yes, it has a built-in printer for on-the-spot report generation.
It is portable and suitable for various clinical settings.
It plays a crucial role in assessing fetal well-being and ensuring a healthy pregnancy and delivery.

Reviews

There are no reviews yet.


Be the first to review “Bionet FC1400 Fetal Monitor (CTG Machine)”

Related Products