Masimo Rad-97™ Pulse CO-Oximeter

Rs. 87,000.00
  • Masimo Rad-97 Pulse CO-Oximeter is a compact, configurable bedside patient monitor offering continuous noninvasive SpO₂ and pulse rate monitoring with advanced rainbow SET technology. Optional parameters, connectivity, rechargeable battery, touchscreen display, and NIBP or capnography configurations support clinical monitoring.
SKU:
Get photos/videos on WhatsApp
Our advantages
  • GST Invoice available
  • Mail /SMS notification
  • Easy Return and exchange
  • Multiple payment options
  • Best price
Payment options
  • Credit/Debit Card Payment
  • Netbanking and UPI Payment
  • NEFT or RTGS to Bank Account
  • Easy EMI on selected products
  • Partial COD payment on delivery
Similar Categories
Categories: Pulse Oximeter
Description

The Masimo Rad-97™ Pulse CO-Oximeter is an advanced, compact bedside patient monitor designed for continuous, noninvasive monitoring of multiple physiological parameters. Powered by Masimo SET® Measure-through Motion and Low Perfusion™ pulse oximetry and upgradeable rainbow SET® technology, Rad-97 provides clinicians with comprehensive patient information in a configurable format.

The device can monitor SpO₂, pulse rate (PR), perfusion index (Pi), and Pleth Variability Index (PVi), with optional rainbow parameters such as total hemoglobin (SpHb), carboxyhemoglobin (SpCO), methemoglobin (SpMet), oxygen content (SpOC), and respiration rate. Depending on configuration, Rad-97 is also available with integrated noninvasive blood pressure (NIBP) or NomoLine® capnography.

Its responsive multi-touch display, customizable interface, audible and visual alarms, rechargeable battery, and connectivity options make the Rad-97 Pulse CO-Oximeter suitable for hospitals, clinics, critical-care environments, and other professional healthcare applications.

Specification

Product Name:Masimo Rad-97™ Pulse CO-Oximeter

Device Type:Bedside Pulse CO-Oximeter

Monitoring Technology:Masimo SET® & upgradeable rainbow SET®

SpO₂:Oxygen Saturation

Pulse Rate (PR):Continuous pulse rate monitoring

Perfusion Index (Pi):Available

Pleth Variability Index (PVi):Available

Total Hemoglobin (SpHb):Optional / configuration dependent

Carboxyhemoglobin (SpCO):Optional / configuration dependent

Methemoglobin (SpMet):Optional / configuration dependent

Oxygen Content (SpOC):Optional / configuration dependent

Respiration Rate:Acoustic RRa® or pleth-derived RRp®, depending on configuration

Oxygen Reserve Index (ORi):Available depending on configuration/market

NIBP:Optional integrated configuration

Capnography:Optional NomoLine® configuration

Display:High-resolution color multi-touch display

Display Orientation:Automatic rotation

Alarms:Audible and visual

Connectivity:Enterprise Wi-Fi / compatible connectivity systems

Power:AC power with rechargeable battery

Mounting:Suitable for mobile roll stand

Application:Professional bedside patient monitoring

Monitoring Type:Noninvasive and continuous

FAQ

1. What is the Masimo Rad-97 Pulse CO-Oximeter?

The Masimo Rad-97 is a compact bedside Pulse CO-Oximeter designed for continuous, noninvasive monitoring of oxygen saturation, pulse rate and additional physiological parameters using Masimo SET® and rainbow SET® technologies.

2. What parameters does Rad-97 measure?

Standard monitoring includes SpO₂, pulse rate, perfusion index (Pi), and Pleth Variability Index (PVi). Depending on configuration, additional parameters such as SpHb, SpCO, SpMet, SpOC and respiration rate can be available.

3. Does the Masimo Rad-97 measure SpCO?

Yes. SpCO (carboxyhemoglobin) is available through the upgradeable rainbow SET® technology, subject to the applicable device configuration and compatible sensor.

4. Can Rad-97 measure total hemoglobin?

Yes. SpHb (total hemoglobin) is one of the optional rainbow SET® parameters supported by compatible Rad-97 configurations.

5. Is Rad-97 available with blood pressure monitoring?

Yes. A Rad-97 configuration with integrated noninvasive blood pressure (NIBP) is available. It supports spot-check, automatic interval, and stat interval blood-pressure measurement modes.

6. Does Rad-97 have capnography?

Yes. The Rad-97 with NomoLine® Capnography configuration provides continuous EtCO₂ monitoring along with respiration rate and other respiratory information.

7. Is the Masimo Rad-97 suitable for bedside monitoring?

Yes. Rad-97 is specifically designed as a bedside patient monitor and can also be mounted on a mobile roll stand for greater mobility within clinical environments.

8. Does Rad-97 have a touchscreen?

Yes. The device features a responsive, high-resolution color multi-touch display with customizable data presentation and automatic display rotation.

9. Can Rad-97 connect to hospital information systems?

Yes. Rad-97 includes enterprise Wi-Fi connectivity that can support compatible Masimo connectivity solutions and integration with electronic medical record workflows.

10. What makes Masimo Rad-97 different from a standard pulse oximeter?

Unlike a basic pulse oximeter that primarily displays oxygen saturation and pulse rate, Rad-97 is an advanced bedside monitoring platform capable of continuous pulse CO-oximetry and, depending on configuration, additional hemoglobin, dyshemoglobin, oxygen-content, respiration, blood-pressure and capnography measurements.